Multi-Zone Gas Monitor
Industry Leading Precision Monitoring for Low-level Gas Leak Detection
Bacharach’s Multi-Zone Gas Monitor provides precise measurements enabling early leak detection for compliance with refrigeration safety codes (ASHRAE 15, EN 378, CSA-B52) and emissions reduction standards (F-Gas, CARB).
- Proprietary infrared (NDIR) sensor accurately detects the presence of a target gas down to an industry-leading 1 ppm Minimum Detection Level (MDL)
- Sensor is not prone to false alarms caused by cross-interference from other gases or sudden changes in temperature or humidity
- Gas library contains 60+ refrigerants, including CFCs, HFCs, HCFCs, HFOs and natural refrigerants (R-744, R-717)
- Backlit display shows real-time concentration readings and makes configuration and self-diagnostics intuitive
- Capable of monitoring up-to 16 zones (expandable up to 48 sample points) and detecting multiple gases with a single monitor
- Two optional analog outputs (4-20mA) and Modbus communications (slave) for integration with third-party BMS / BAS control systems
- Three user-configurable relays (leak, spill and evacuate) may be used to activate external beacons / sounders, ventilation or other countermeasures
Product Information
Bacharach’s Multi-Zone Gas Monitor delivers the best refrigerant leak detection available, with industry-leading MDL of 1ppm for halogenated gases, the fastest sampling frequency and the widest range of refrigerants accurately detected. The large graphic LCD display and LED status indicators provide a system-wide overview at a glance.
The Multi-Zone enhances effective refrigerant management and ensures compliance with refrigeration safety standards (ASHRAE 15, EN 378, CSA-B52) and emissions regulations (F-Gas, CARB RMP). It detects leaks early to enable cost savings by reducing refrigerant recharge, enhancing energy efficiency and reducing risk of refrigeration failure and produce loss. A variety of communication interfaces are available including Modbus, BACnet and LonWorks, allowing easy integration into BMS / BAS systems and remote monitoring solutions.
Product Specifications
Sensor Channels: | 4 to 16 |
Sample Points: | 48 |
Measuring Range: | Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm |
Sensitivity / Minimum Detection Limit: | Refrigerants: 1 ppm, Ammonia: 10 ppm, Carbon Dioxide: 10 ppm |
Accuracy: | ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2) |
Resolution: | 1 ppm |
Enclosure Rating: | General Purpose |
Sampling Distance: | 0 to 1,200′ (0 to 365 m) |
User Interface: | Backlit, graphic LCD 160 x 128 pixel; three status LEDs |
Power: | 100 to 240 VAC, 50/60 Hz, 20W |
Analog Communications: | 4 to 20 mA (optional) |
Digital Communications: | Modbus RTU via RS 485 |
Operating Voltage: | 100 to 240 VAC, 50 / 60 Hz |
Relay Rating: | 3 alarm relays, 1 fault relay, SPDT |
Wiring: | 5 A @ 250 VAC, resistive load |
Alarm: | Integrated Audible / Visual Alarm |
Ambient Temperature: | 32 to 122°F (0 to 50°C) |
Humidity: | 5 to 90 %RH, non condensing |
Altitude: | 0 to 6,560 ft (2,000 m) |
Status Indicator: | LCD, LEDs |
Buzzer Volume: | 80 dB @ 10 cm |
Product Dimensions (L×W×H): | 13.7” × 12.3” × 5” (350 × 315 × 130 mm) |
Product Weight: | 15 lbs. (6.8 kg) |
Sensor Type: | NDIR |
Expected Sensor Service Life: | 10 Years |
Approvals: | CE, UL, CSA, EN 61010-1, EN 61326, EN 14624 |
Warranty: | 2 Years |
Country of Origin: | United States |
Accessories and Parts
HGM-RD, Remote Display Module (See Technical Library for Instruction Manual) |
Audible / Visual Alarm, 110 VAC, Blue Strobe |
Audible / Visual Alarm, 120 VAC, Red Strobe |
Horn + Strobe 24 V DC – Blue Lens |
Strobe – Blue Lens – MP120K 120 V AC Adapter |
Horn + Strobe 24 V DC – Red Lens |
Strobe – Red Lens – MP120K 120 V AC Adapter |
Horn + Strobe 24 V DC – Amber Lens |
Strobe – Amber Lens – MP120K 120 V AC Adapter |
Air Sample Tubing (250 ft. / 76 m roll) |
Air Sample Tubing – AMMONIA ONLY (500 ft. / 152 m roll) |
Air Sample Tubing Coupling, Quick Disconnect |
Splitter Kit, 2-way, includes line end filters and brackets (Not for use w/NH3) |
Splitter Kit, 3-way, includes line end filters and brackets(Not for use w/NH3) |
R-22 Gas Verification Kit |
R-134a Gas Verification Kit |
R-123 Gas Verification Kit |
Variable Flow Regulator |
1031 Cylinder, 100 ppm R-22 |
1031 Cylinder, 100 ppm R-134a |
1031 Cylinder, 100 ppm R-123 |
120 VAC Surge Protector |
4-20 mA DC Surge Protector |
Wall-Mount Uninterruptable Power Supply (UPS) Backup |
BacNet Communications Module Package |
N2 (JCI Metasys) Communications Package |
Lon Works Communications Package |
4 Zone Expansion Kit (max of 3 per MZ) Note: Must also order 3015-3411 |
Dual 4-20 mA DC output PC board |
Line End Filter Only |
Line End Filter Assembly |
Charcoal Filter Assembly with Fittings |
Charcoal Filter Mounting Bracket |
Splash/Spray-Resistant End of Line Filter Assembly |
Hydrophobic Filter (Internal Water Stop) |
Inline Water Trap |
Inline Water Trap, Replacement Filter Element |
Line End Water Stop |
Sample Pump |
Supported Gases
Contact Us
To speak to a member of our friendly customer service team about any of our products or services, please do not hesitate to contact us on the details below:
Telephone: (+44) 1527 522 299